Main content
Introducing the tablet-based Oxford Cognitive Screen-Plus (OCS-Plus) as an assessment tool for subtle cognitive impairments.
- Anonymous Contributors
Date created: | Last Updated:
: DOI | ARK
Creating DOI. Please wait...
Category: Project
Description: Objective Here, we present the Oxford Cognitive Screen-Plus, a computerised tablet-based screen designed to briefly assess domain-general cognition and provide more fine-grained measures of memory and executive function. The OCS-Plus was designed to sensitively screen for cognitive impairments and provide a differentiation between memory and executive deficits. Methods The OCS-Plus contains 10 subtasks and requires approximately 20 minutes to complete. In this study, 320 neurologically healthy ageing participants (age M=62.66, SD=13.75) from three sites completed the OCS-Plus to provide a normative sample. The convergent validity of this assessment was established in comparison to the ACE-R, CERAD and Rey-Osterrieth. Divergent validity was established through comparison with the BDI. Internal consistency of each subtask was evaluated, and test-retest reliability was determined. Results We established the normative impairment cut-offs for each of the subtasks. Predicted convergent and divergent validity was found, high internal consistency for most measures was also found with the exception of restricted range tasks, as well as strong test-retest reliability, which provided evidence of test stability. Further research demonstrating the use and validity of the OCS-Plus in various clinical populations is required. Conclusion The OCS-Plus is presented as a standardised cognitive assessment tool, normed and validated in a large sample of neurologically healthy participants. The OCS-Plus will be available as an Android App and provides an automated report of domain-general cognitive impairments in executive attention and memory.
Our pre-print is live here -- https://psyarxiv.com/b2vgc/ with a DOI 10.31234/osf.io/b2vgc. You can find a PDF version in this repository under the folder Pre-print.
All raw data, R project file, and reproducible analysis pipeline through an RMardown code document can be found in the folder Final Scripts and Data.
Our data is summarised (descriptives and distributions as well as descriptions of th…
Files
Files can now be accessed and managed under the Files tab.
Components
Recent Activity
Unable to retrieve logs at this time. Please refresh the page or contact support@osf.io if the problem persists.